Quantitation of SU1 1248, an oral multi-target tyrosine kinase inhibitor, and its metabolite in monkey tissues by liquid chromatograph with tandem mass spectrometry following semi-automated liquid-liquid extraction.
Article Details
- CitationCopy to clipboard
Baratte S, Sarati S, Frigerio E, James CA, Ye C, Zhang Q
Quantitation of SU1 1248, an oral multi-target tyrosine kinase inhibitor, and its metabolite in monkey tissues by liquid chromatograph with tandem mass spectrometry following semi-automated liquid-liquid extraction.
J Chromatogr A. 2004 Jan 23;1024(1-2):87-94.
- PubMed ID
- 14753710 [ View in PubMed]
- Abstract
SU11248 is a potent inhibitor of PDGFR, VEGFR, KIT, and Flt3, and is currently under Phase I clinical evaluation as an anticancer drug. A sensitive and specific analytical method for the quantitation of SU11248 and its metabolite in several monkey tissues (liver, kidney, brain and white fat) using LC-MS-MS following semi-automated liquid-liquid extraction (LLE) was developed and validated. Amounts of 50 mg of tissue were homogenized using an ultrasonic processor. After addition of the stable labelled internal standard (IS) and ammonium hydroxide (0.3%), samples were extracted with 2.5 ml of tert-butyl methyl ether. Following centrifugation, aliquots of 1.8 ml of the organic phase were transferred into a 96-well plate. The Packard Multiprobe II robotic liquid handler was used to perform all steps mentioned above. The organic phase was dried and the residue was reconstituted with 800 microl of 15 mM ammonium formate buffer solution (pH 3.25) using a Tomtec Quadra 96 workstation. Aliquots of 10 microl of the resulting solution were injected into the LC-MS-MS system. A Symmetry Shield C8 column (50 mm x 2.1 mm, 3.5 microm) was used to perform the chromatographic analysis. The mobile phase was 15 mM ammonium formate buffer solution (pH 3.25)-acetonitrile (74:26 (v/v)) with a flow-rate of 0.35 ml/min. Retention times of the metabolite and SU11248 were about 2.5 and 3.5 min, respectively. Total cycle time was 5 min. MS detection used the Applied Biosystems-MDS Sciex API 3000 with TurbolonSpray interface and multiple reaction monitoring (MRM) operated in positive ion mode. The method was validated for both compounds over the calibration range of about 2 and 2000 ng/g. The suitability and robustness of the method for in vivo samples were confirmed by analysis of monkey tissues from animals dosed with SU11248.
DrugBank Data that Cites this Article
- Drug Targets
Drug Target Kind Organism Pharmacological Action Actions Sunitinib Mast/stem cell growth factor receptor Kit Protein Humans YesInhibitorDetails Sunitinib Platelet-derived growth factor receptor beta Protein Humans YesInhibitorDetails Sunitinib Receptor-type tyrosine-protein kinase FLT3 Protein Humans YesInhibitorDetails Sunitinib Vascular endothelial growth factor receptor 2 Protein Humans YesInhibitorDetails